AG Scientific beta-Lactamase, Extended Spectrum

List Price $323.49 Your Price $323.49
AG Scientific beta-Lactamase Extended Spectrum has a broad spectrum activity of complete inactivation over a broad range of cephalosporins and penicillins (Additional S&H Or Hazmat Fees May Apply) - AG
NETA PART: RPI-L-2467-1KU
MFG.PART: L-2467-1KU
UNSPSC: 12352204
Manufacturer: AG Scientific
AG Scientific

Description:

beta-lactamasesare enzymesproduced by bacteria (Also known as Penicillinase) that provideresistancetoβ-lactam antibioticssuch as penicillins, cephamycins, andcarbapenems(ertapenem), although carbapenems are relatively resistant to beta-lactamase.

​​​beta-lactamase provides antibiotic resistance by breaking the antibiotics structure. These antibiotics all have a common element in their molecular structure: a four-atom ring known as aβ-lactam. Throughhydrolysis, the lactamase enzyme breaks the β-lactam ring open, deactivating the molecules antibacterial properties.

beta-lactam antibiotics are typically used to treat a broad spectrum ofGram-positiveandGram-negativebacteria. beta-lactamases produced by Gram-negative organisms are usually secreted, especially when antibiotics are present in the environment.

β-Lactamase is a freeze-dried product containing buffer salts and zinc. β-Lactamase-ES has a broad spectrum activity of complete inactivation over a broad range of cephalosporins and penicillins.

Advantages:

  • Full inactivation of a broad range of beta-Lactams including the more resistant cephalosporins: Cefepime, Cefoxitin, Cefradine and Ceftazidime which other commercially available enzymes do not degrade as efficiently.
  • Highly stable, retaining >90% of its activity after 4 hours at 50°C, means no need to compensate for loss of enzyme activity during media preparation for applications using sterile plates.

Applications:

  • Testing sterility of blood cultures -Blood cultures are routinely prepared in order to test for bacterial infection. False negative results might be obtained where the blood sample contains antibiotics. Incorporation of β-Lactamase in the culture medium will overcome this problem when cephalosporins/penicillins are present.
  • Testing for contamination of drugs by antibiotics -US Code of Federal regulations states that “If a reasonable possibility exists that a non-penicillin drug product has been exposed to cross-contamination with penicillin, the non-penicillin drug product shall be tested for the presence of penicillin” (21 CFR 211.176, Penicillin Contamination, FDA, BY-Lines No. 8 November 1977).
  • Environmental monitoring of antibiotic manufacturing area.
  • Sterility testing of Bulk antibioticsas described by US Pharmcopeia (USP) Chapter 71 and EP Section 2.6.

Activity:

  • Sterile, ready to use vials:>50 units/vial
  • Non-sterile, bulk: >2 U/mg powder

Specifications:

  • Sterile, gamma-irradiated, pre-dispensed, vacuum sealed vials (in packs of 10) for speed and ease of use
  • 1 KU is approximately 0.31 g
  • 1 Vial is approximately 30-50 mg
  • pH Activity Range: Active at ph 6.5 - 9.8
  • Temperature stability: >90% at 50°C for 4 hours
  • Bulkpowder is not sterile, but has been filtered through a 0.45 micron filter prior to freeze drying.

Reconstitution Protocol for Sterile, Ready to Use Vials:

Reconstitute at 10 U/mL with sterile water. Sterile-filter through a 0.45μm membrane filter into sterile media.For agar media, add to liquid agar medium at >40°C just prior to pouring agar plates.


Potency in Agar Medium: Use at 0.5 U/mL in agar plates for complete (100%) hydrolysis of all Beta-lactams.

Unit Definition:
One unit of beta-Lactamase activity is defined as the amount of enzyme that will catalyze the hydrolysis of 1.0 micromole of cephalosporin C per minute at 25°C and pH 7.0

One beta-Lactamase unit is equivalent to 600 Levy Units, 75 Pollock Units, or 91200 Kersey Kinectic Units

Sterility:

  • beta-Lactamase vials are sterilized by gamma-irradiation. No detectable growth in Tryptone Soya broth at 20°C to 25°C or Thioglycollate at 30°C to 35°C for 14 days.
  • Bulkpowder is not sterile, but has been filtered through at 0.45 micron filter prior to freeze drying.

Additional Reading:

​​​​​

(Additional S&H Or Hazmat Fees May Apply) - AG
More Information
SKU RPI-L-2467-1KU
Featured No
Supplier Part Number L-2467-1KU
UM EA
UNSPSC 12352204
Manufacturer Name AG Scientific
MSDS URL Click here
Temperature 4°C
Refrigerated-Frozen Y
CountryOfOrigin United Kingdom
ProductLine AG
Qty 1
MinOrderQty 1
Weight 5.000000
Lead Time 5
Hazardous N
CAS Number 9073-60-3
ACT Ecolabel No